BLUVISION

Discrete analyzer

Skalar BLUVISION analyzer
Methods and options are selected based on your application.

Every reaction.
Its own space.

With BLUVISION, each colorimetric determination runs in its own cuvette. The instrument handles dispensing, mixing and measuring so your lab can focus on reviewing the results.

Analytical principle
Discrete colorimetry
Reaction vessel
Disposable cuvettes
Analysis control
Touchscreen and DiscreteAccess

Capabilities

One platform.
Automated analyses.

See how the work is organized inside the instrument, from loading to reading.

100

sample positions

Samples and reagents

Five racks of 20 positions to organize the samples. The sample and reagent carriers can be cooled during the analysis.

160

cuvettes on the tray

Individual reactions

The tray holds 160 individual cuvettes and keeps the temperature controlled during the reaction.

Up to640

consecutive tests

Automated loading

The autoloader adds new cuvette blocks automatically. Unattended run time depends on the methods and the consumables available.

These figures show loading capacity and the number of consecutive tests; they do not represent samples analyzed per hour.

Technology

From dispensing
to result.

Four coordinated stages within one system.

01 / Dispensing

BLUVISION dispensing needle
BLUVISION dispensing needle
01DispensingSample and reagents, in the specified ratio.

The needle picks up and dispenses sample and reagents, and can also preheat them before dispensing. Preparing calibrations from concentrated standards and automatic dilutions reduce manual tasks.

02ReactionOne cuvette for each determination.

Disposable cuvettes keep the reactions separate. The instrument mixes the sample with the reagents and controls the reaction temperature.

03ReadingFrom color development to measurement.

The photometer measures the color developed during the reaction. DiscreteAccess lets you schedule dilutions and re-analyze samples outside the defined range.

04ResultsTracking the run and its results.

DiscreteAccess lets you add priority samples, prepare reports and export to Excel or LIMS. If a sample falls outside the defined range, it can be measured again at a different dilution, depending on the configured method.

Applications

Water.
Its parameters.

For laboratories that test drinking water, wastewater, surface water or groundwater. The method is selected based on the sample type and the concentrations you need to measure.

  • Alkalinity
  • Ammonia
  • Nitrate + nitrite
  • Nitrite
  • Ortho-phosphate
  • Chloride
  • Sulfate
  • Silicate
  • Calcium
  • Magnesium
  • Total hardness
  • Iron

These are some of the available parameters. Check compatibility with your sample type and analytical method.

Frequently asked questions

Before you choose
your BLUVISION.

What is the difference between discrete analysis and continuous flow?

In BLUVISION, reactions take place in individual cuvettes. In a continuous flow system, the sample travels through analytical modules. The choice depends on your determinations and the way you work.

Do the sample positions show how many tests it runs per hour?

No. The positions show how many samples the instrument can hold. Throughput depends on the methods, reaction times, dilutions and controls included in the run.

What information do you need to evaluate my application?

The type of water, the parameters, the expected concentrations, the reference methods and the daily workload. With this information we can determine whether the instrument is right for your application.

Are the cuvettes reused?

No. They are disposable and supplied in blocks. It’s a good idea to factor in their consumption when planning lab operations.

Can I export the results?

DiscreteAccess lets you export results and prepare reports. The connection to your management system should be reviewed against the lab’s format and requirements.

Can I add an urgent sample?

Yes. DiscreteAccess lets you add samples during a sequence. This helps you handle priorities without setting up a completely new run.

How is waste handled?

Used blocks are collected in a container. The instrument also offers chemical waste separation depending on the method. Final disposal must follow the lab’s safety procedures.

BLUVISION in operation

Your next BLUVISION

Let’s talk about
your application.

Tell us what you need to measure. We’ll review the sample, method and workload to guide the choice of instrument.

You can also write to us

contacto@ugs-international.com.mx

Fields marked * are required.

Your information will be used to handle and follow up on your request. Privacy notice in Spanish (opens in a new tab).

How we handle your data

U.G.S. INTERNATIONAL S.A. DE C.V., located at Sierra Tarahumara 207, Lomas de Chapultepec, 11000 Mexico City, will use your identification and contact data, the information in your request and technical data from the submission to respond to you, prepare the service or quote you requested, follow up with you and protect the form. We do not request sensitive personal data, and sending an inquiry does not subscribe you to advertising. You may limit the use or disclosure of your data and exercise your rights by writing to contacto@ugs-international.com.mx.